Calibrators & Verification Standards for Clinical Analyzers

Calibrators and verification standards for clinical chemistry, immunoassay and specialty analyzers - single-point and multi-point calibrators with assigned target values, calibration verification and linearity sets, and reference standards from Bio-Rad, Randox and platform-specific suppliers. Supplied as graded multi-level panels across the analytical measurement range with lot-specific value-assignment documentation. Materials are matched to analyzer and reagent system and reordered on schedule with reagent lot changes. Wholesale case pricing and standing order programs for laboratory procurement, materials management and licensed distributors.

Aegis Scientific # HW-NIST-CERT
NIST SLF CERTIFICATION KT
Special Order/Non-Stock
2,015.89
Advanced Instruments # 3MA085
CALIBRATIN STANDR 850MOSM
Ships within 24 Hours
160.86
Advanced Instruments # 3MA005
CALIBRATIN STANDR 50MOSM
Ships within 24 Hours
159.91
Advanced Instruments # 3LA201
STANDARD, CALIBRATION 2000MOSM10X5ML
Ships within 24 Hours
152.36
Advanced Instruments # 3LA151
CALIBRATN STANDR 1500MOSM
Ships within 24 Hours
183.20
Advanced Instruments # 3LA091
CALIBRATIN STANDR 900MOSM
Ships within 24 Hours
183.20
Advanced Instruments # 3LA028
OSMOLALITY LINEAR 5LVL ST
Ships within 24 Hours
224.39
Advanced Instruments # 3LA011
CALIBRATIN STANDR 100MOSM
Ships within 24 Hours
183.20
Advanced Instruments # 3LA010
CALIBRATIN STANDR 100MOSM
Ships within 24 Hours
84.91
Abbott # 06F1101
Simulator f/Electronic QC Ea
Special Order/Non-Stock
1,274.21
Aalto Scientific # K728M-5
Beta-Hydroxybutyric Acd Lin LQ 1mL 5/Bx
Ships within 24 Hours
472.63
Aalto Scientific # K723M-5
MicroCV Urine/ Fluids Linearity Set 5 Level 10x3mL f/ Analyzer Ea
Ships within 24 Hours
403.40
Alfa-Wassermann # SA1029
Ace Ise Calibrator A 300ml 3/Bx
Ships within 24 Hours
263.04
Alfa-Wassermann # S2-85
URINE STANDARD
Ships within 24 Hours
215.69
Alfa-Wassermann # S1-33
Calibrators for Chemistry Analyzers, GEMCAL Reference Serum Calibrator, 5 x 3.0 mL
Ships within 24 Hours
169.55
Alfa-Wassermann # E1-2
Ace Ise Calibrator B 3x90ml Pk
Ships within 24 Hours
273.98
Alfa-Wassermann # C2-85
URINE CONTROL
Ships within 24 Hours
188.16
Alfa-Wassermann # C1-5
LEVEL 2 CHEMISTRY CONTROL
Ships within 24 Hours
155.60
Alfa-Wassermann # C1-4
LEVEL 1 CHEMISTRY CONTROL
Ships within 24 Hours
155.60
Alere # 98015XR
Triage BNP XR C/V Calibrator Level A-E Kit
Ships within 24 Hours
161.21
Alere # 88770
LIPID/GLU CALIB/VERIFICAT
Ships within 24 Hours
157.36
Alere # 88755
Triage Total Control Cal Ver 5/BX
Ships within 24 Hours
127.17
Azer Scientific # ES7001
MULTI-ANALYTE CHEMSITRY CALIBRATOR L2, EACH
Ships within 24 Hours
166.15
Azer Scientific # ES7000
MULTI-ANALYTE CHEMSITRY CALIBRATOR L1, EACH
Ships within 24 Hours
166.15
Azer Scientific # ES5040
LIPOPROTEINS , CALIBRATION, EACH
Ships within 24 Hours
515.25
Azer Scientific # ES5020
MULTI-ANALYTE LINEARITY CONTROL, EACH
Ships within 24 Hours
483.51
Azer Scientific # ES5011
BILIRUBIN LINEARITY CONTROL, EACH
Ships within 24 Hours
408.86
Azer Scientific # ES5001
BLOOD GAS / ELECTROLYTE LINEARITY, 3X5X2M, EACH
Special Order/Non-Stock
844.11
Audit Microcontrols # K886M-5
LINEARITYFD BILI REAGENT
Ships within 24 Hours
106.87
Audit Microcontrols # K882M5
LINEARITY FD LIPID RGNT
Ships within 24 Hours
472.63
Audit Microcontrols # K880M5
LINEARITY FD GEN CHEM
Ships within 24 Hours
443.98
Audit Microcontrols # K851M-5
TOSOH T UPTAKE LINEARITY
Ships within 24 Hours
125.87
Audit Microcontrols # K841M-5
PROCALCITONIN LINEAR SET
Ships within 24 Hours
472.63
Audit Microcontrols # K809M-5
LINEARITY IMMUNOAS ANEMIA
Ships within 24 Hours
193.35
Audit Microcontrols # K808M-5
SIEMENS IMMUNO ASSAY FERT
Ships within 24 Hours
274.50
Audit Microcontrols # K807M-5
IMMUNOASSAY LINEARITY THY
Ships within 24 Hours
140.12
Audit Microcontrols # K805M-5
SIEMENS TUMOR MARK LIN ST
Ships within 2-4 Days
695.63
Audit Microcontrols # K804M-5
Cardiac Markers Linearity Set Ea
Ships within 24 Hours
472.63
Audit Microcontrols # K803M-5
MICRO CV BNP LINEARIT SET
Ships within 24 Hours
472.63
Audit Microcontrols # K801M-5
Centaur Homocystine Linearity 5x1ml Ea
Ships within 24 Hours
472.63
Audit Microcontrols # K729M-5
VITAMIN D LINEARITY SET
Ships within 24 Hours
281.66
Audit Microcontrols # K727M-5
BLOOD GAS LINEARITY TEST
Ships within 24 Hours
472.63
Audit Microcontrols # K726M-5
AUDIT ISE LINEARITY TEST
Ships within 24 Hours
203.69
Audit Microcontrols # K722M-5
MICRO ALBUMIN/PROTEIN LIN
Ships within 24 Hours
472.63
Audit Microcontrols # K721M-5
MICROCV ASO LINEARITY SET
Ships within 24 Hours
472.63
Audit Microcontrols # K720M-5
MICROCV RF/CRP LINEARITY
Ships within 24 Hours
472.63
Audit Microcontrols # K717M-5
D-DIMER LOW LINEARITY SET
Ships within 24 Hours
519.69
Audit Microcontrols # K712M-5
Ammonia/Ethanol Linearity 1ml 5/St
Ships within 24 Hours
485.42
Audit Microcontrols # K710M-5
Audit Cardiac Marker Linearity 1ml 5/St
Ships within 24 Hours
472.63
Audit Microcontrols # K709M-5
Audit Lipids Linearity 1ml 5/St
Ships within 24 Hours
472.63

Calibrators and Verification Standards for Analyzer Accuracy

Calibrators and verification standards are the reference materials a laboratory uses to set analyzer response and confirm that reported values stay accurate across the reportable range. This category stocks single-point and multi-point calibrators with assigned target values, calibration verification and linearity sets, and analytical measurement range validators for clinical chemistry, immunoassay and specialty platforms. Materials are matched to analyzer and reagent system and supplied at wholesale case pricing.

Calibrator and Standard Types Stocked

  • Multi-analyte chemistry calibrators - Calibrators with assigned target values for panels of chemistry analytes, used to set analyzer response for named platforms and reagent systems.
  • Single-analyte and specialty calibrators - Dedicated calibrators for individual assays such as enzymes, proteins, lipids and specialty markers where a platform requires assay-specific calibration.
  • Linearity and calibration verification sets - Graded panels, typically five or six levels, that span the analytical measurement range to confirm linearity and validate the reportable range.
  • Immunoassay calibrators - Calibrators with assigned values for immunoassay markers, supplied to match the analyzer's calibration protocol.
  • Reference and traceability standards - Materials with values traceable to recognized reference methods, used to support accuracy verification and method comparison.

Widely stocked lines include Bio-Rad calibration verification and linearity products and Randox calibrator and verification materials, alongside platform-specific calibrators supplied to match the reagent system in use.

Calibrators Compared to Verification Standards

MaterialPurposeFormatValue Assignment
CalibratorSet analyzer response before patient testingSingle or multi-point vialsAssigned target values per assay
Calibration verification setConfirm calibration remains valid over timeMulti-level panelAssigned values across the range
Linearity setConfirm linear reporting across the AMR5-6 graded levelsGraded concentration values
Reference standardSupport accuracy and traceability checksVialed materialTraceable to reference methods

Traceability and Value Assignment

Calibrators and verification standards carry assigned values documented on the manufacturer's value-assignment sheet, with many lines reporting traceability to recognized reference methods or materials. Values are lot-specific, so replacement lots are ordered on a schedule that aligns with reagent lot changes and calibration verification intervals. Documentation supplied with each lot covers assigned values, uncertainty where provided, and the analyzers and methods the material is intended for.

Calibration and verification materials are a lot-linked consumable that laboratories reorder continuously to keep analyzers in calibration and to meet calibration verification requirements under accreditation programs. Because lots must be on hand before existing material expires, procurement teams schedule these SKUs as standing orders tied to reagent and control lot cycles. MAP Medical supplies calibrators, linearity and verification sets in case quantities for laboratory accounts. Order at the best Wholesale Prices with MAP Medical.


Frequently Asked Questions


What is the difference between a calibrator and a linearity set?

A calibrator sets an analyzer's response at one or more points so that patient results are reported accurately. A linearity set is a graded panel of five or six levels used to confirm that the analyzer reports accurately across the full analytical measurement range and that the reportable range remains valid. Calibrators establish the calibration; linearity sets verify it holds across concentrations. Both are stocked here and matched to the analyzer platform.

What does traceability mean for a calibrator?

Traceability means the calibrator's assigned values are linked, through documented steps, to a recognized reference method or reference material. This supports accuracy and comparability of results between laboratories and analyzers. Products in this category report traceability on the value-assignment sheet supplied with each lot, along with the methods and platforms the calibrator is intended for.

How many levels are in a calibration verification or linearity panel?

Calibration verification and linearity panels are typically supplied as five or six graded levels spanning the analytical measurement range, from low through high. Some assay-specific sets use a different level count. The exact configuration and assigned values are listed on each product and its lot documentation.

Can laboratories order calibrators and verification standards in bulk?

Yes. Calibrators, linearity sets and verification standards are stocked in case quantities for hospital laboratories, reference and independent labs, physician-office labs and licensed distributors. Standing order programs align replacement lots with reagent lot changes and calibration verification schedules. Contact our procurement team for tiered case pricing and standing order setup.

What calibration materials should be included in a laboratory formulary?

A calibration formulary typically includes the platform-specific calibrators required for each analyzer's chemistry and immunoassay menu, a calibration verification or linearity set for each measurement range that requires periodic verification, and any reference standards used for accuracy checks. Composition follows the analyzer roster and accreditation requirements. MAP Medical builds consolidated calibration and verification packages matched to platform and test menu - contact our team for an assessment.