Vacuum, Suction, Evacuation and Waste Management
Vacuum, suction, evacuation and waste management systems for the dental operatory - dry and wet-ring vacuum pumps, high-volume evacuation (HVE) valves and tips, saliva ejectors, evacuation traps and canisters, and amalgam separators from DentalEZ Ramvac, Air Techniques, Midmark, Tech West and Solmetex. Amalgam separators meet the ISO 11143 standard referenced by the EPA dental effluent rule. Stocked for new vacuum systems and for daily evacuation consumables. Wholesale and project pricing for practices and group practices.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vacuum, Suction and Evacuation Systems for the Operatory
Operatory evacuation runs from the HVE and saliva ejector at the chair through traps and separators to the central vacuum pump. This category groups the pumps, valves, tips, traps and amalgam separators that build and service that system, stocked as capital equipment and as the daily evacuation consumables.
Vacuum and Evacuation Component Types Stocked
- Vacuum pumps - Dry and wet-ring central vacuum pumps sized by simultaneous-user count for the operatory. Lines include DentalEZ Ramvac, Air Techniques VacStar and Midmark.
- HVE valves and tips - High-volume evacuation valves, quick-disconnect HVE and saliva ejector valves, and single-use HVE and surgical suction tips.
- Saliva ejectors and tips - Single-use saliva ejectors, disposable HVE tips and aspirator tips in stocked lengths and tip styles.
- Traps, canisters and filters - Solids collectors, evacuation traps, canister filters and screens that capture debris before the vacuum pump.
- Amalgam separators - ISO 11143 amalgam separators such as Solmetex NXT Hg5, with replacement collection cartridges, for capturing amalgam waste ahead of the drain.
Vacuum System Components
| Component | Type | Function | Representative Brands |
|---|---|---|---|
| Vacuum pump | Dry or wet-ring | Central suction source | DentalEZ Ramvac, Air Techniques, Midmark |
| HVE valve and tip | Reusable valve, single-use tip | High-volume evacuation | DentalEZ, Tech West |
| Saliva ejector | Single-use | Low-volume suction | Generic, OEM |
| Trap and filter | Consumable | Debris capture | OEM-matched |
| Amalgam separator | ISO 11143 unit | Amalgam waste capture | Solmetex NXT Hg5, Rebec |
Dry and Wet Vacuum and Amalgam Compliance
Central vacuum is stocked in dry and wet-ring designs. Dry vacuum pumps use no process water and are sized by the number of simultaneous users; wet-ring pumps use a water ring to create suction. Amalgam separators that meet the ISO 11143 standard are the compliance point referenced by the EPA dental effluent rule for practices that place or remove amalgam, and they are stocked with replacement collection cartridges for scheduled service.
Vacuum pumps and separators are capital and semi-capital equipment, while HVE tips, saliva ejectors, traps, filters and amalgam cartridges are high-turnover consumables reordered in every supply cycle. Stocking the daily evacuation consumables alongside the pumps and separators keeps every operatory's suction in service, and case pricing applies to the disposable lines. Order at the best Wholesale Prices with MAP Medical.
Browse Related Categories
Evacuation systems capture waste from the delivery units and chairs and connect to the scavenging circuits of the nitrous oxide sedation systems. Pump and valve service parts overlap with equipment electronics, cables and repair parts. Return to the dental equipment catalog or the full dental catalog.
Frequently Asked Questions
What is the difference between dry and wet-ring vacuum pumps?
Dry vacuum pumps generate suction without process water and are sized by the number of simultaneous users, which reduces water use. Wet-ring pumps use a recirculating or single-pass water ring to create the vacuum. Both are stocked and sized to operatory count. The choice depends on the practice's water and utility setup, which is a facility decision.
Do amalgam separators meet the EPA dental rule?
The amalgam separators stocked meet the ISO 11143 standard that the EPA dental effluent rule references for practices that place or remove amalgam. Units such as the Solmetex NXT Hg5 are stocked with replacement collection cartridges for scheduled changes. The catalog supplies the equipment and cartridges; compliance recordkeeping is the facility's responsibility.
Which evacuation items are single-use consumables?
Single-use consumables include HVE tips, saliva ejectors, surgical aspirator tips, evacuation traps and screens, canister filters and amalgam separator collection cartridges. The HVE and ejector valves, vacuum pump and separator housing are durable equipment. Consumables are reordered by the case and separator cartridges on a scheduled cycle.
Can practices order vacuum systems and consumables in bulk or by project?
Yes. Vacuum pumps and amalgam separators are quoted by project, and HVE tips, saliva ejectors, traps, filters and separator cartridges are stocked in case and bulk quantities for practices, group practices, dental service organizations and licensed distributors. Standing order programs are available for the highest-velocity SKUs. Contact our procurement team for tiered case pricing and standing order setup.
What evacuation items should be in a practice formulary?
A core evacuation formulary typically covers a standing supply of single-use HVE tips and saliva ejectors, evacuation traps and screens, vacuum line cleaner, replacement HVE and ejector valves, and amalgam separator collection cartridges for practices that place or remove amalgam. MAP Medical builds consolidated evacuation packages matched to operatory count and pump brand - contact our team for an assessment.